相思资源网 Design By www.200059.com
From:http://support.microsoft.com/kb/2015129

Symptoms

  Consider the following scenario. You install the .NET Framework 4.0. Then, you install an earlier version of the .NET Framework, or you enable .NET 3.0 WCF HTTP Activation. In this scenario, you may receive the following error message when you when run applications that are hosted on Internet Information Services (IIS):

Could not load type 'System.ServiceModel.Activation.HttpModule' from assembly 'System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089'. 
Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code.

Exception Details: System.TypeLoadException: Could not load type 'System.ServiceModel.Activation.HttpModule' from assembly 'System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089'.

 

Cause

  This issue occurs because the Applicationhost.config file for Windows Process Activation Service (WAS) has the following section defined, and this section is incompatible with the .NET Framework 4.0:

<add name="ServiceModel" type="System.ServiceModel.Activation.HttpModule, System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" preCondition="managedHandler" />

  This section should be defined as follows:

<add name="ServiceModel" type="System.ServiceModel.Activation.HttpModule, System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" preCondition="managedHandler,runtimeVersionv2.0" />

  Note You can find the Applicationhost.config file in the following location:

%windir%\system32\inetsrv\config

 

Resolution

  To resolve this issue, run the following command line: 

aspnet_regiis.exe /iru

  The Aspnet_regiis.exe file can be found in one of the following locations:

%windir%\Microsoft.NET\Framework\v4.0.30319

%windir%\Microsoft.NET\Framework64\v4.0.30319 (on a 64-bit computer)

 

注意

  以上方案在win8系统中无效,因为在最后一步运行 aspnet_regiis.exe /iru 命令时会失败,所以解决方案是找到 Applicationhost.config 文件(目录在%windir%\system32\inetsrv\config),然后把文件中的:

<add name="ServiceModel" type="System.ServiceModel.Activation.HttpModule, System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" preCondition="managedHandler" />

  改为:

<add name="ServiceModel" type="System.ServiceModel.Activation.HttpModule, System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" preCondition="managedHandler,runtimeVersionv2.0" />

  我目前只找到这种方案,如果有更好方案欢迎指出。

作者:Artwl
出处:http://artwl.cnblogs.com

标签:
ServiceModel,HttpModule

相思资源网 Design By www.200059.com
广告合作:本站广告合作请联系QQ:858582 申请时备注:广告合作(否则不回)
免责声明:本站文章均来自网站采集或用户投稿,网站不提供任何软件下载或自行开发的软件! 如有用户或公司发现本站内容信息存在侵权行为,请邮件告知! 858582#qq.com
相思资源网 Design By www.200059.com

评论“win8 Could not load type System.ServiceModel.Activation.HttpModule 错误解决方案”

暂无win8 Could not load type System.ServiceModel.Activation.HttpModule 错误解决方案的评论...

RTX 5090要首发 性能要翻倍!三星展示GDDR7显存

三星在GTC上展示了专为下一代游戏GPU设计的GDDR7内存。

首次推出的GDDR7内存模块密度为16GB,每个模块容量为2GB。其速度预设为32 Gbps(PAM3),但也可以降至28 Gbps,以提高产量和初始阶段的整体性能和成本效益。

据三星表示,GDDR7内存的能效将提高20%,同时工作电压仅为1.1V,低于标准的1.2V。通过采用更新的封装材料和优化的电路设计,使得在高速运行时的发热量降低,GDDR7的热阻比GDDR6降低了70%。